Filter Results By:

Products

Applications

Manufacturers

High Voltage Dividers

scales down very high voltage in order to measure. AKA: HV Dividers

See Also: Voltage Dividers, HV Dividers


Showing results: 31 - 34 of 34 items found.

  • HV Calibration

    B-1027 - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation’s High Voltage Calibration Lab provides high accuracy capability for conducting tough reliability tests on all our high voltage devices. In this facility we test and calibrate HV Relays, HV Dividers, HV Probes, Spark Gaps, our Fiber Optic Systems, and HV Digital Voltmeters up to 450kV. We provide our own in house test lab to ensure Ross products meet or exceed required safety standards as well as our own high standards of dependability, long life and quality. Our technicians use test equipment calibrated by or traceable to National Institute of Standards and Technology or other national metrology institute to provide the highest in testing accuracy.

  • High Frequency Clock Divider Board

    Alliance Support Partners, Inc.

    Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.

  • HV Probes & Multimeters

    B-1010, B1010-A, B-1012, B-1012-A - ROSS ENGINEERING CORPORATION

    HV Probes and Voltmeters for oscilloscopes, DVMs, recorders. HV DC, AC & Wideband DC-10MHz. Safety probes for any scope, digital display or recorder. Also available complete with large 4½ digit display 0.01% to 5% DC/AC accuracy digital voltmeter, with safety handles for OSHA recommended personnel clearances. With attached or separate digital display or multimeter 0.00001V to 400kV. HV Digital Multimeters. Wideband DC-10MHz. VMD2A 4½ digit portable meter has accuracies to 0.01% DC, 0.1% 50/60Hz, 3% DC-1MHz, 3dB to 10MHz. True RMS, Avg, True +PK, -PK, PK to PK, 0.2 microsecond, 1/2 sine single pulse capture & hold. 0.00001V - 1000V DC or PK AC and for use with HV Probes to 400kV and Voltage Dividers to 1,000,000V. Has 2V output to scope, recorder. To 1000kV with HV divider, DC-10MHz.

  • HV Voltage Dividers

    ROSS ENGINEERING CORPORATION

    *DC up to 10MHz*1kV to 1,200kV DC or PK AC*To 1,875kV Impulse*To ±0.01% DC Accuracy Accredited*To ±0.2% AC Accuracy (50/60Hz) Accredited*To ±3% DC-1MHz Wideband*±3dB 5 to 30 MHz*Compact & Lightweight*For Oscilloscopes*For Recorder*For Digital Multimeters*Very Partial Discharge/Low Corona*Very Low Phase Shift*Resistive*Capacitance*Compensated Wideband*Indoor & Outdoor*Electronic and Power Class*Match Wideband Differential*High Voltage Power Quality Instrumentation

Get Help